Int Ophthalmol ; 44(1): 200, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38662305

RESUMO

PURPOSE: To analyse real-world outcomes in Asian eyes of iStent inject, a second-generation trabecular micro-bypass stent, combined with phacoemulsification. METHODS: This is a multi-centre, observational study of glaucomatous Asian eyes that have undergone iStent inject implantation combined with cataract surgery. Patient data were extracted from the Fight Glaucoma Blindness! Registry. Outcome measures included those of IOP reduction, glaucoma medication reduction, and adverse events including the need for secondary surgery. RESULTS: 123 eyes of 86 patients with a mean age of 68.4 ± 9.3 years underwent iStent inject implantation with phacoemulsification. At baseline, the mean ± SD preoperative intraocular pressure (IOP) was 16.0 ± 4.4 mmHg, and the mean preoperative number of topical glaucoma medications was 1.9 ± 1.4. At 12 months 30.8% of eyes demonstrated a reduction in IOP greater than 20%, the mean IOP reduction was 12.5% with an additional reduction of 0.7 glaucoma medications. 40% of eyes were using no medications at 12 months compared to 16.3% preoperatively. 8.2% of eyes required a subsequent procedure within the 12-month follow-up window. CONCLUSION: iStent inject implantation combined with phacoemulsification in Asian eyes showed a reduction of IOP and glaucoma medication use in a real-world clinical setting. The safety profile of the device is good with minimal adverse outcomes, however, a subset of patients required secondary procedures within the 12 month follow up.


Assuntos
Pressão Intraocular , Sistema de Registros , Humanos , Masculino , Feminino , Idoso , Pressão Intraocular/fisiologia , Pessoa de Meia-Idade , Implantes para Drenagem de Glaucoma , Austrália/epidemiologia , Acuidade Visual , Resultado do Tratamento , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/etnologia , Glaucoma/complicações , Facoemulsificação/métodos , Seguimentos , Idoso de 80 Anos ou mais , Povo Asiático/etnologia , Catarata/complicações , Estudos Retrospectivos
3.
Arq Bras Oftalmol ; 87(6): e2021, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597522

RESUMO

Implantation of glaucoma drainage devices is a valuable therapeutic option, particularly in children with glaucoma refractory to primary surgical treatment. Glaucoma drainage devices are typically used when conjunctival scarring hampers filtration surgery or prior angle procedures are not effective in controlling intraocular pressure. Despite known complications, the use of glaucoma drainage devices in children has increased in recent years, even as the primary surgical option. In this review, we evaluate the results of recent studies involving the implantation of glaucoma drainage devices in children, discussing new advances, and comparing the success rates and complications of different devices.


Assuntos
Doenças da Túnica Conjuntiva , Implantes para Drenagem de Glaucoma , Glaucoma , Criança , Humanos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Pressão Intraocular , Implantação de Prótese/métodos , Estudos Retrospectivos , Resultado do Tratamento
4.
Arq Bras Oftalmol ; 87(3): e20230033, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38537046

RESUMO

PURPOSE: This study aims to compare the initial ocular discomfort symptoms resulting from trabeculectomy and Ahmed glaucoma valve implantation surgeries. METHODS: A prospective comparative study was conducted. The evaluation of ocular discomfort employed a questionnaire designed to identify the frequency and severity of distinct symptoms: ocular pain, general discomfort, tearing, foreign body sensation, and burning. This questionnaire was administered prior to surgery as a baseline, and subsequently at 7, 30, and 90 days post-surgery. Simultaneously, the Ocular Surface Disease Index (OSDI) was applied at these same time intervals. RESULTS: The study encompassed a total of 17 patients (9 undergoing trabeculectomy and 8 undergoing Ahmed glaucoma valve implantation). The Ahmed glaucoma valve implantation group exhibited higher tearing levels at baseline (p=0.038). However, no statistically significant differences in symptoms were observed between the two surgeries at 7 and 30 days post-surgery. At the 90-day mark following surgery, patients who had undergone trabeculectomy reported a significantly higher foreign body sensation (p=0.004). Although OSDI scores did not differ between groups at baseline, the trabeculectomy group showed significantly higher OSDI scores than the Ahmed glaucoma valve implantation group at 7, 30, and 90 days after surgery (p<0.05). CONCLUSION: Post-surgery, patients who had undergone trabeculectomy experienced increased foreign body sensation. Trabeculectomy appears to cause greater early postoperative ocular discomfort compared to the Ahmed glaucoma valve implantation group.


Assuntos
Corpos Estranhos , Implantes para Drenagem de Glaucoma , Glaucoma , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Estudos Prospectivos , Pressão Intraocular , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/etiologia , Implantação de Prótese/efeitos adversos , Corpos Estranhos/complicações , Corpos Estranhos/cirurgia , Resultado do Tratamento , Estudos Retrospectivos
5.
Int Ophthalmol ; 44(1): 150, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38503938

RESUMO

PURPOSE: To assess and compare the risk for development of cystoid macula edema (CME) after glaucoma drainage device (GDD) implantation versus conventional trabeculectomy with mitomycin (trab) for glaucoma. METHODS: Retrospective review of consecutive patients receiving trab or GDD implantation between 2016 and 2018. Inclusion criteria were availability of pre- and postoperative spectral domain optical coherence tomography (SD-OCT) of the macula. SD-OCT images were evaluated for presence of CME qualitatively, central subfield thickness (CST) and macular volume (MV). RESULTS: 73 eyes could be included, 42 received trab and 31 GDD surgery. Eyes receiving trab on average had 0.8 ± 0.8 previous intraocular operations, while eyes with GDD implantation had 3.1 ± 1.9 (p < 0.001). Occurrence of postoperative CME was significantly more frequent after GDD implantation (6 out of 31 (19.4%)) than after trab (2 out of 42 eyes = 4.8%), (p = 0.049). Mean preoperative CST as well as MV was comparable in both groups (CST before trab: 282.7 ± 23.0 µm, CST before GDD 284.2 ± 27.3 µm, p = 0.287; MV before trab: 7.8 ± 1.1 mm3, MV before GDD: 8.0 ± 0.8mm3, p = 0.305). Mean postoperative CST and MV were significantly higher after GDD (CST 338.5 ± 129.3 µm, MV 8.8 ± 2.6 mm3) than after trabeculectomy (CST 290.6 ± 60.2 µm, p = 0.038; MV 7.8 ± 1.2mm3, p = 0.039). CONCLUSIONS: In real-life conditions, GDD surgery seems to be associated with a higher risk to develop CME when compared to conventional trabeculectomy. This information may be helpful for glaucoma surgeons to advise the patients on postoperative risks of surgery.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Edema Macular , Trabeculectomia , Humanos , Trabeculectomia/efeitos adversos , Trabeculectomia/métodos , Pressão Intraocular , Glaucoma/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos , Edema Macular/diagnóstico , Edema Macular/etiologia , Edema Macular/cirurgia , Edema , Estudos Retrospectivos
6.
Medicine (Baltimore) ; 103(12): e37457, 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38518004

RESUMO

PURPOSE: Cosmetic iris implants have a record of high ocular complications and are no longer in use. These complications include glaucoma, corneal decompensation, iris atrophy, uveitis, cataract and retinal detachment. CASE PRESENTATION: We report a case of a 44-year-old lady presented with bilateral total iris atrophy, glaucoma and corneal decompensation after cosmetic artificial iris implantation. The patient underwent bilateral artificial iris removal, glaucoma drainage device for the right eye, and micropulse laser for the left eye. In addition, she underwent phacoemulsification with iris-diaphragm intraocular lens implant for the right. The cornea of the right eye ended up with successful Boston keratoprosthesis after rejection of previous 2 grafts. CONCLUSIONS: To the best of our knowledge, we describe the first report of bilateral total iris atrophy following a cosmetic iris implant accompanied by bilateral glaucoma and corneal decompensation.


Assuntos
Doenças da Córnea , Implantes para Drenagem de Glaucoma , Glaucoma , Doenças da Íris , Feminino , Humanos , Adulto , Doenças da Córnea/complicações , Córnea , Remoção de Dispositivo/efeitos adversos , Pressão Intraocular , Glaucoma/etiologia , Glaucoma/cirurgia , Iris/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos
7.
Acta Ophthalmol ; 102(4): e443-e451, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38376121

RESUMO

To compare the safety and efficacy of the Preserflo Microshunt with trabeculectomy in the treatment of patients with glaucoma. A systematic review and meta-analysis was conducted. The primary outcome measures recorded as a measure of efficacy of the interventions were intra-ocular pressure (IOP) at final follow-up and IOP reduction (IOPR). Secondary outcomes recorded to measure efficacy were reduction in the number of glaucoma medications and reinterventions. To assess safety profile, the proportions of patients with post-operative complications were recorded. Seven articles were included in this study. A total of 1353 eyes were included in this review (Preserflo: 812, trabeculectomy: 541). Post-operative IOP (mean difference [MD] = 0.78 [0.66, 0.90], p < 0.001) results are significantly lower for trabeculectomy than Preserflo. The IOPR (MD = -1.20 [-2.30, -0.09], p = 0.034) results significantly favour trabeculectomy over Preserflo Microshunt. The reduction in topical glaucoma medications (MD = -0.32 [-0.58, -0.07], p = 0.014) is significantly higher for trabeculectomy. There is no statistically significant difference in levels of hypotony (risk ratio [RR] = -0.05 [-0.47, 0.37], p = 0.806), choroidal effusion/detachment (RR = -0.12 [-0.42, 0.19], p = 0.444), hyphaema (RR = 0.20 [-0.11, 0.51], p = 0.216) and flat anterior chamber (RR = 0.49 [-1.02, 0.03], p = 0.066). There are significantly more bleb-related complications in the trabeculectomy groups than Preserflo groups (RR = -0.63 [-1.01, -0.24], p = 0.001). There were statistically more reinterventions required in the trabeculectomy groups than Preserflo groups (RR = -0.48 [-0.65, -0.30], p < 0.001). Compared to trabeculectomy, the Preserflo Microshunt is not as effective in lowering intra-ocular pressure, has a similar safety profile and has a lower reintervention rate. Further research is required given the lack of randomised controlled trials within this study and resulting low strength of evidence.


Assuntos
Glaucoma , Pressão Intraocular , Trabeculectomia , Humanos , Trabeculectomia/métodos , Pressão Intraocular/fisiologia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Resultado do Tratamento , Implantes para Drenagem de Glaucoma , Ácido Hialurônico/administração & dosagem , Implantação de Prótese/métodos
8.
Indian J Ophthalmol ; 72(3): 352-356, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38421291

RESUMO

BACKGROUND: Neovascular glaucoma (NVG) is a secondary glaucoma with a poor visual prognosis. Trabeculectomy with antifibrotic agents, glaucoma drainage devices (GDDs), and cyclo-destructive procedures are recommended in patients who are refractory to medical management. However, due to the poor success rate of conventional trabeculectomy and the higher cost of GDDs, alternative procedures need to be looked at. PURPOSE: To compare the surgical outcomes and economic aspects of a newly developed polypropylene suture bed-based modified trabeculectomy to Ahmed glaucoma valve (AGV) implantation for NVG. METHODS: It was a prospective interventional study conducted at a tertiary care center between 2018 and 2020. Consecutive patients with NVG with a minimum follow-up of 18 months were included. Surgical outcomes are mainly based on intraocular pressure (IOP) control and the cost of surgery. RESULTS: Sixty eyes were included out of which 40 (60.6%) underwent modified trabeculectomy and 20 (33.7%) underwent AGV. At the final follow-up, no significant difference (P < 0.05) was found between the surgical outcomes of both groups. The complete success rate (IOP < 21 mm Hg without antiglaucoma medications) was 60 and 65% while the qualified success rate (IOP < 21 mm Hg with antiglaucoma medications) was 30 and 25% in modified trabeculectomy and AGV groups, respectively, at final follow-up. The cost of surgery was significantly higher in the AGV group (P < 0.0001). CONCLUSION: Modified trabeculectomy as described might be a better alternative for NVG eyes.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma Neovascular , Glaucoma , Trabeculectomia , Humanos , Glaucoma Neovascular/cirurgia , Polipropilenos , Agentes Antiglaucoma , Estudos Prospectivos , Glaucoma/cirurgia
9.
Int Ophthalmol ; 44(1): 25, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38326580

RESUMO

PURPOSE: To investigate the clinical outcomes of Ahmed glaucoma valve (AGV) implantation in primary open-angle glaucoma (POAG) and pseudoexfoliative glaucoma (PEXG). METHODS: The patients who underwent AGV implantation for POAG and PEXG between January 2015 and December 2021 in a single tertiary center eye clinic were reviewed retrospectively. Thirty-one eyes with the diagnosis of POAG constituted Group 1 and 40 eyes with the diagnosis of PEXG constituted Group 2. The primary outcome measures were intraocular pressure (IOP) changes after AGV implantation and surgical success at the last visit. We evaluated complete and qualified surgical success using the following three criteria: (1) IOP ≤ 21mmH g, (2) IOP ≤ 18 mmHg, and (3) IOP ≤ 15 mmHg, as well as the absence of any serious complications, such as light perception loss and phthisis bulbi, and additional de novo glaucoma surgery. RESULTS: The mean follow-up times were 25.2 (± 21.4) months and 27.6 (± 19.8) months for Groups 1 and 2, respectively (p > 0.05). In Groups 1 and 2, the mean preoperative IOPs were 31.9 ± 9.4 mmHg and 32.3 ± 8.4 mmHg, respectively, which significantly reduced to 14.5 ± 0.7 mmHg and 11.6 ± 0.6 mmHg, respectively at the last postoperative visit (p < 0.001 for both). The mean IOP value at the last visit was statistically significantly lower in Group 2 (p = 0.006). At the last visit, the number of eyes with qualified success according to criteria 1, 2, and 3 was 26 (83.9%), 25 (80.6%), and 18 (58.1%), respectively, in Group 1 and 39 (97.5%), 39 (97.5%), and 32 (80%), respectively, in Group 2. The comparison of the qualified success rates showed statistically significantly higher rates in Group 2 for criterion 2 (p = 0.038). CONCLUSION: AGV implantation had high success rates in both POAG and PEXG, but at the final visit, lower IOP levels were reached in the latter.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Glaucoma de Ângulo Aberto/complicações , Estudos Retrospectivos , Seguimentos , Resultado do Tratamento , Glaucoma/cirurgia , Pressão Intraocular
10.
Int Ophthalmol ; 44(1): 45, 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38336985

RESUMO

PURPOSE: To describe the in toto explantation of the CyPass® Micro-Stent and its conceivable complications. METHODS: This is a case series of eighteen eyes from fourteen patients who underwent CyPass® Micro-Stent implantation due to mild to moderate glaucoma and who subsequently suffered from loss of endothelial cell density. Consequently, the CyPass® Micro-Stent was in toto explanted. The surgical procedure and its complications are described and compared with trimming of the CyPass® Micro-Stent. RESULTS: A postoperative hyphema was developed in 8 of the 18 eyes. In four of them the hyphema was self-limiting, while in two patients an anterior chamber irrigation was necessary. One patient suffered from a severe intracameral bleeding and iridodialysis during explantation, so that the base of the iris had to be scleral fixated. The remaining explantations were without complications. CONCLUSION: Dealing with implanted CyPass® Micro-Stents poses a challenge for ophthalmic surgeons. An in toto removal can be traumatic, since the CyPass stent often is fibrotic encapsulated and fused with the surrounding tissue. Alternatively, trimming of the CyPass is also a viable option to avoid further endothelial damage. Reported complications of CyPass trimming are consistent with those that can occur after explantation. Further data on the development of the endothelial cells after trimming or explantation are not yet available. Therefore, it remains open whether trimming of the CyPass, in contrast to complete removal, carries the risk of further endothelial cell loss.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Compostos de Quinolínio , Tiazóis , Humanos , Pressão Intraocular , Células Endoteliais , Hifema , Glaucoma de Ângulo Aberto/cirurgia , Implantes para Drenagem de Glaucoma/efeitos adversos , Câmara Anterior , Stents/efeitos adversos , Complicações Pós-Operatórias
11.
Sci Rep ; 14(1): 4452, 2024 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396005

RESUMO

To carry out the preclinical and histological evaluation of a novel nanotechnology-based microshunt for drainage glaucoma surgery. Twelve New Zealand White rabbits were implanted with a novel microshunt and followed up for 6 weeks. The new material composite consists of the silicone polydimethylsiloxane (PDMS) and tetrapodal Zinc Oxide (ZnO-T) nano-/microparticles. The microshunts were inserted ab externo to connect the subconjunctival space with the anterior chamber. Animals were euthanized after 2 and 6 weeks for histological evaluation. Ocular health and implant position were assessed at postoperative days 1, 3, 7 and twice a week thereafter by slit lamp biomicroscopy. Intraocular pressure (IOP) was measured using rebound tonometry. A good tolerability was observed in both short- and medium-term follow-up. Intraocular pressure was reduced following surgery but increased to preoperative levels after 2 weeks. No clinical or histological signs of inflammatory or toxic reactions were seen; the fibrotic encapsulation was barely noticeable after two weeks and very mild after six weeks. The new material composite PDMS/ZnO-T is well tolerated and the associated foreign body fibrotic reaction quite mild. The new microshunt reduces the IOP for 2 weeks. Further research will elucidate a tube-like shape to improve and prolong outflow performance and longer follow-up to exclude medium-term adverse effects.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Óxido de Zinco , Animais , Coelhos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Glaucoma/etiologia , Pressão Intraocular , Tonometria Ocular , Câmara Anterior/cirurgia , Nanotecnologia
12.
Sci Rep ; 14(1): 3777, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38355702

RESUMO

Glaucoma drainage devices (GDDs) are prosthetic-treatment devices for treating primary open-angle glaucoma. Despite their effectiveness in reducing intraocular pressures (IOP), endothelial cell damage (ECD) is a commonly known side-effect. There have been different hypotheses regarding the reasons for ECD with one being an induced increase in shear on the corneal wall. A computational fluid dynamics (CFD) model was used to investigate this hypothesis in silico. The Ahmed Glaucoma Valve (AGV) was selected as the subject of this study using an idealised 3D model of the anterior chamber with insertion angles and positions that are commonly used in clinical practice. It was found that a tube-cornea distance of 1.27 mm or greater does not result in a wall shear stress (WSS) above the limit where ECD could occur. Similarly, a tube-cornea angle of 45° or more was shown to be preferable. It was also found that the ECD region has an irregular shape, and the aqueous humour flow fluctuates at certain insertion angles and positions. This study shows that pathological amounts of WSS may occur as a result of certain GDD placements. Hence, it is imperative to consider the associated fluid force interactions when performing the GDD insertion procedure.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Glaucoma de Ângulo Aberto/cirurgia , Hidrodinâmica , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Pressão Intraocular , Células Endoteliais , Resultado do Tratamento , Estudos Retrospectivos , Seguimentos , Implantação de Prótese
13.
Arch Soc Esp Oftalmol (Engl Ed) ; 99(3): 98-108, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38216051

RESUMO

BACKGROUND AND OBJECTIVE: Recommendations on general glaucoma management and the use of early minimally invasive and microincisional surgeries are limited. This study aimed to establish consensus regarding glaucoma management, focusing on the XEN-45 gel stent implant. METHODS: A Delphi consensus-driven process was used. The scientific committee led the study, identified the expert panel, and participated in elaborating the questionnaire. Fifty-one panelists were invited to complete, on a nine-point Likert scale, an 89-item questionnaire covering three topic blocks. Two Delphi rounds were performed. Consensus was achieved if ≥66.6% of panelists reached agreement or disagreement. RESULTS: Panelists agreed on 84 items related to the patients' quality of life, the therapeutic algorithm and patient profile, and surgical and pre- and post-operative management. Panelists agreed on the suitability of XEN stent implants to treat glaucoma at different stages and for different patient profiles: young patients, elderly or with significant comorbidities, and with myopic glaucoma, patients who failed previous surgeries, and with previous poor post-operative experience. XEN surgery was considered a therapeutic step prior to classic filtering surgery and a possible first surgical option in elderly patients with comorbidities and uncontrolled intraocular pressure. XEN surgery allows the patient to return to routine daily activities faster than conventional filtering surgeries and to reduce and/or eliminate topical treatments. CONCLUSIONS: This Delphi-driven consensus resulted in a series of general recommendations for glaucoma management, including those related to patient quality of life, therapeutic algorithm, and patient profile, and specific ones regarding the use of XEN stent gel surgery.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Idoso , Técnica Delfos , Qualidade de Vida , Resultado do Tratamento , Glaucoma/cirurgia
14.
J Glaucoma ; 33(5): e21-e23, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38194276

RESUMO

PURPOSE: This case report aims to describe a new method for increasing intraocular pressure (IOP) in patients with acute hypotony resulting from uveitis flare-ups and preexisting glaucoma drainage devices. The temporary glaucoma tube plug method described is effective and safe. METHODS: This case report presents a 47-year-old female patient with a history of chronic panuveitis and secondary glaucoma, who had 2 previously implanted Ahmed glaucoma valves. The patient developed panuveitis flare-up and persistent hypotony. A novel method of ab interno plugging of the glaucoma tubes using 2-0 prolene suture plugs was performed. Following treatment, the IOP increased successfully and remained within the normal range. CONCLUSION: The temporary ab interno glaucoma tube plug method effectively increased IOP in a patient with 2 preimplanted Ahmed glaucoma valves with persistent low IOP due to uveitis.


Assuntos
Implantes para Drenagem de Glaucoma , Pressão Intraocular , Hipotensão Ocular , Humanos , Feminino , Pessoa de Meia-Idade , Pressão Intraocular/fisiologia , Hipotensão Ocular/fisiopatologia , Hipotensão Ocular/etiologia , Hipotensão Ocular/diagnóstico , Hipotensão Ocular/cirurgia , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Glaucoma/complicações , Implantação de Prótese , Tonometria Ocular , Acuidade Visual/fisiologia , Técnicas de Sutura
15.
J Glaucoma ; 33(5): 310-316, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38194266

RESUMO

PRCIS: Longer-term studies with a larger sample size are needed to demonstrate the superiority or equivalence of these procedures. OBJECTIVE: To evaluate the outcomes of the PAUL glaucoma implant (PGI) and Ahmed glaucoma valve (AGV) in patients with secondary glaucoma caused due to silicone oil emulsification. PATIENTS AND METHODS: A retrospective examination was conducted using the medical records of 36 patients who developed secondary glaucoma due to silicone oil emulsification after vitreoretinal surgery and then underwent PGI and AGV implantation surgery. The main outcome measures in the PGI and AGV groups were intraocular pressure (IOP) and its change, the number of antiglaucoma medications, and postoperative complications during the 12-month follow-up period. IOP of <6 mm Hg is used to define hypotonia. RESULTS: There was no statistically significant difference among the patients who underwent PGI and AGV surgeries in terms of IOP averages, both preoperatively and postoperatively on day 1, week 1, month 1, month 3, month 6, and month 12 ( P > 0.05). Before PGI and AGV implantation, the mean IOP was 40 ± 13 mm Hg and 39.3 ± 10 mm Hg, and the mean number of medications was 3.8 ± 0.4 and 4 ± 0, respectively. At the end of the 12-month follow-up period, the mean IOP was 13.5 ± 2.2 ( P < 0.001) mm Hg and 14.9 ± 4.2 ( P < 0.001) mm Hg, whereas the mean number of glaucoma medications decreased to 1.7 ± 1.3 ( P < 0.001) and 1.9 ± 1.8 ( P < 0.001) in the PGI and AGV groups, respectively. Surgical success was achieved in 17 of 18 eyes (94%) in the PGI group and 16 of 18 eyes (89%) in the AGV group. CONCLUSIONS: Although the outcomes were similar in both the PGI and AGV groups, complications requiring medical and surgical intervention were less common in the PGI group. Longer-term studies with a larger sample size are needed to demonstrate the superiority or equivalence of these procedures.


Assuntos
Implantes para Drenagem de Glaucoma , Pressão Intraocular , Óleos de Silicone , Tonometria Ocular , Acuidade Visual , Humanos , Pressão Intraocular/fisiologia , Estudos Retrospectivos , Feminino , Masculino , Óleos de Silicone/administração & dosagem , Pessoa de Meia-Idade , Acuidade Visual/fisiologia , Adulto , Resultado do Tratamento , Glaucoma/cirurgia , Glaucoma/fisiopatologia , Implantação de Prótese , Seguimentos , Idoso , Anti-Hipertensivos/administração & dosagem , Anti-Hipertensivos/uso terapêutico , Complicações Pós-Operatórias , Cirurgia Vitreorretiniana
17.
BMC Ophthalmol ; 24(1): 4, 2024 Jan 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172748

RESUMO

BACKGROUND: Determine outcomes of concurrent strabismus surgery with placement of a glaucoma drainage device (GDD) in children. METHODS: Retrospective review of pediatric patients who underwent simultaneous lateral rectus (LR) muscle surgery with superotemporal GDD placement. Strabismus and GDD success were defined as residual horizontal misalignment < 10 prism diopter (PD) and intraocular pressure (IOP) < 21 mmHg, no visually devastating complications, and no additional IOP-lowering surgeries. RESULTS: Fifteen eyes of 13 patients (69% male) underwent LR surgery (14 recessions, 1 resection) for exotropia or esotropia simultaneous with GDD placement (13 Baerveldt, 2 Ahmed) at 8.34 ± 5.26 years. Preoperative visual acuity (VA) in operative eye (0.89 ± 0.54) was worse than non-operative eye (0.23 ± 0.44, p = 0.0032). Preoperative horizontal deviation was 38.3 ± 9.4 PD and LR recession was 7.4 ± 1.1 mm. At final follow-up, VA in operative eye (0.87 ± 0.52) was unchanged from preoperative (p = 0.4062). Final IOP was significantly decreased (12.4 ± 4.7 mmHg vs. 31.1 ± 11.4 mmHg, p = 0.0001) as was number of glaucoma medications (2.7 ± 1.7 vs. 1.1 ± 1.3, p = 0.0037). Five (38%) and 9 patients (69%) met criteria for strabismus and GDD success, respectively. Two eyes required tube revision and endoscopic cyclophotocoagulation and 2 eyes had additional strabismus surgery. CONCLUSIONS: Concurrent strabismus and GDD surgery decreased horizontal deviation and obtained IOP control. It is important to consider correction of strabismus at time of GDD placement to maximize visual development and improve cosmesis in children with glaucoma.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Estrabismo , Humanos , Masculino , Criança , Feminino , Resultado do Tratamento , Glaucoma/complicações , Glaucoma/cirurgia , Pressão Intraocular , Implantação de Prótese , Estrabismo/cirurgia , Estudos Retrospectivos , Seguimentos
18.
Eur J Ophthalmol ; 34(1): NP27-NP31, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37192674

RESUMO

BACKGROUND: To discuss the efficacy of an inferior implant of XEN 63 gel stent in a patient with refractory glaucoma after trabeculectomy failure and vitreoretinal surgery with silicone oil tamponade. CASE DESCRIPTION: We report the case of a 73-year-old man with a history of refractory open glaucoma with trabeculectomy failure. He experienced recurrent retinal detachments with silicone oil tamponade, with uncontrolled intra-ocular pressure (IOP) after silicone oil removal. Due to the presence of oil emulsion in the anterior chamber, the chosen location for XEN 63 implantation was the infero-temporal quadrant. Mild hyphema and vitreous hemorrhage were seen post-operatively, but were self-limiting. At week 1, the intraocular pressure was 8 mmHg with a well-formed bleb seen in anterior segment optical coherence tomography (AS-OCT). At 6 month follow up, the patient maintained a IOP of 12 mmHg without topical hypotensive drugs. Slit lamp examination revealed a widespread, developed bleb with no signs of inflammation. CONCLUSION: In this case of refractory glaucoma in a vitrectomized eye with previous oil tamponade, the inferior placement of the XEN 63 gel stent delivered an adequate intraocular pressure even at 6-months follow up, with a diffuse functional infero-nasal bleb seen with AS-OCT.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Masculino , Humanos , Idoso , Glaucoma de Ângulo Aberto/cirurgia , Óleos de Silicone/efeitos adversos , Implantes para Drenagem de Glaucoma/efeitos adversos , Glaucoma/cirurgia , Pressão Intraocular , Stents/efeitos adversos
19.
J Glaucoma ; 33(2): 132-138, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37974333

RESUMO

PRCIS: In this study, we report a 2-year follow-up after implantation of an adjustable glaucoma drainage device combined with a novel orbital filtering plate. The IOP was efficiently controlled postoperatively with limited complications and an excellent safety profile. PURPOSE: To report the clinical results at 2 years after implantation of an eyeWatch (eW) system, which comprises an adjustable glaucoma drainage device (eW implant) combined with a novel orbital filtering plate (eyePlate), in refractory glaucoma. PATIENTS AND METHODS: Monocentric, prospective, noncomparative clinical trial. Patients suffering from refractory glaucoma after several failed surgeries were operated using the eW system. The primary outcome was the success rate, defined as an IOP ≤18 mm Hg and reduction of more than 20% from baseline, IOP ≥6 mm Hg. Secondary outcomes were mean IOP, visual acuity, the number of antiglaucoma medications, and the number and type of complications. RESULTS: Forty-two eyes from 42 patients were included. The mean follow-up time was 22.0±4.0 months. The mean baseline IOP decreased from 23.2±7.2 mm Hg before surgery to 11.9±4.4 mm Hg at 12 months ( P <0.001) and 11.5±3.0 at 24 months. The mean number of glaucoma medications decreased from 2.9±0.9 before surgery to 0.7±0.9 at 12 months ( P <0.001) and 1.0±0.9 at 24 months. The qualified success rate was 93% at 12 months and 90% at 24 months whereas the complete success rate was 46% and 40% at 12 and 24 months, respectively. Complications occurred in 7 patients. CONCLUSIONS: Implantation of the eW system effectively lowered IOP and reduced glaucoma medications for a 2-year period in patients who had previously failed glaucoma surgery. Persistent hypotony was not observed and the number of complications was low.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Humanos , Estudos Prospectivos , Pressão Intraocular , Implantação de Prótese/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Glaucoma/complicações , Implantes para Drenagem de Glaucoma/efeitos adversos , Seguimentos , Estudos Retrospectivos
20.
J Glaucoma ; 33(2): 116-125, 2024 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-37853674

RESUMO

PRCIS: Ab externo with open conjunctiva placement may lead to improved gelatin stent (XEN Gel Stent; Allergan) success rate compared with ab interno with closed conjunctiva because it conferred more favorable intraocular pressure (IOP) and medication burden reduction based on our complete and qualified success criteria. PURPOSE: To compare outcomes of a gelatin stent (XEN 45 Gel Stent; Allergan) placed either ab interno with closed conjunctiva (AIC) or ab externo with open conjunctiva (AEO) with or without cataract surgery in patients with glaucoma. DESIGN: Retrospective, nonrandomized comparative study of 85 eyes from 85 glaucoma patients who received XEN 45 Gel Stent placed either AIC (N=32) or AEO (N=53) with or without cataract surgery between July 2018 and January 2022 at Massachusetts Eye and Ear. Patients were included if they were 18 years of age or above and had at least 30 days of follow-up without any disqualifying event. RESULTS: Baseline demographics were similar between both groups, except for the glaucoma type. Both AIC and AEO procedures resulted in significant patterns of IOP and medication reduction from baseline up to 1 year. At postoperative year (POY)1, mean IOP was reduced to 11.34±4 mmHg on 1.29±1.34 medications after AEO and 13.70±3.32 mmHg on 2±1.81 medications after AIC. The average IOP reduction was significantly greater in the AEO group at all postoperative time points beyond postoperative week 2. There were significant differences in the survival curves of AEO and AIC groups under both the complete success criteria and the qualified success criteria. Under the complete success criteria, the cumulative probability of survival at POY1 was 28.5% in the AEO group and 3.8% in the AIC group. Under the qualified success criteria, the cumulative probability of survival at POY1 was 60.3% in the AEO group and 21.9% in the AIC group. CONCLUSIONS: In our study, we demonstrate that both placements reduce IOP and medication from baseline, with AEO placement having more favorable success rates compared with AIC placement.


Assuntos
Catarata , Implantes para Drenagem de Glaucoma , Glaucoma de Ângulo Aberto , Glaucoma , Humanos , Lactente , Pressão Intraocular , Glaucoma de Ângulo Aberto/cirurgia , Gelatina , Estudos Retrospectivos , Resultado do Tratamento , Glaucoma/cirurgia , Túnica Conjuntiva , Stents